Subscribe: Kyoritsu Indonesia
http://kyoritsu-indonesia.blogspot.com/feeds/posts/default?alt=rss
Preview: Kyoritsu Indonesia

Kyoritsu Indonesia





Last Build Date: Thu, 15 Feb 2018 03:44:18 +0000

 



Kyoritsu Indonesia - KEW 4105DL

Tue, 06 Feb 2018 08:15:00 +0000

Kyoritsu Indonesia - Earth TestersKEW 4105DL 4105DL [Cable Reel Set Model] NEW4105DL-H [Hard Case Model] NEW• 3pole and 2pole Earth Resistance measurement (0.01Ω-2000Ω)• Waterproof design (IP67)• Rotary Switch makes the user interface very intuitive• Large LCD Display with Backlight• Led to monitor correct / non correct auxiliary earth spike resistance• Earth Voltage Measurement (AC/DC 0-300V)• CAT Ⅳ 100V Cable Reel Set ModelHard Case ModelEarth resistancemeasurement20Ω200Ω2000ΩMeasuring range0.00 - 2000 ΩDisplay range0.00 - 20.99 Ω0.0 - 209.9 Ω0 - 2099 ΩAccuracy*1±1.5%rdg±0.08 Ω*2±1.5%rdg±4dgtAuxiliary earth resistance*3<10kΩ <50kΩ <100kΩComparator reference value10Ω 100Ω 500ΩEarth voltage measurementMeasuring range0 - 300 V AC (45 - 65Hz)±0 - ±300 V DCDisplay range0.0 - 314.9 V0.0 - ±314.9 VAccuracy±1%rdg±4dgtOverload protectionEarth resistance : 360V AC (10 seconds)Earth voltage : 360V AC (10 seconds)Applicable StandardsIEC 61010-1, CAT IV 100 V /CAT III 150 V /CAT II 300 V Pollution degree 3IEC 61010-2-030,IEC 61010-031, IEC 61557-1, -5IEC 60529 IP67, IEC 61326-1, -2-2, EN50581(RoHS)Power sourceLR6(AA)(1.5V) × 6Dimensions121(L) × 188(W) × 59(H) mm (including case lid)WeightApprox. 690g (including batteries and case lid)Accessoriesfor 4105DL 7127B(Simplified measurement probe)8041(Auxiliary earth spikes[2 spikes/1set])9121(Shoulder strap)7267(Cable reel for Earth resistance tester (red))7268(Cable reel for Earth resistance tester (yellow))7271(Earth resistance test leads)9190(Carrying case)LR6(AA) × 6, Instruction manualAccessoriesfor 4105DL-H7127B(Simplified measurement probe)8041(Auxiliary earth spikes[2 spikes/1set])9121(Shoulder strap) 7266(Earth resistance test leads[red-20m, yellow-10m, green-5m/1set])9191(Hard case)LR6(AA) × 6, Instruction manualOptional7272(Precision measurement Cord set)8259(Adapter for measurement terminal)*1 For precision measurement, auxiliary earth resistance should be 100 Ω ±5% or less.*2 At simplified measurement add ±0.10 Ω to the specified accuracy.*3 Accuracy within the auxiliary earth resistance: ±5% rdg ±10 dgt.Accessories/Optional Accessories /Related ProductsMODEL 7266MODEL 7127BMODEL 8041MODEL 9121MODEL 9190MODEL 9191MODEL 7272MODEL 8259[...]



Kyoritsu Indonesia - MODEL 4105A

Tue, 06 Feb 2018 08:13:00 +0000

Kyoritsu Indonesia - Earth TestersMODEL 4105A • Dust and drip proof.(designed to IEC 60529 IP54)• In addition to the facility for precision measurement, test leads for simplified two wire easuring system also supplied as standard accessories.(unit can be hung from the neck for simplified measurement)• Designed to meet IEC 61010-1 safety standard.• Capable of measuring earth voltage.• Automatic warning when resistance of auxiliary earth spikes is in excess of tolerance.• Small and lightweight. Shock resistant new case material.• 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test. 4105A Soft Case Model4105A-H Hard Case ModelMeasurement rangesEarth Resistance: 0 - 20Ω/0 - 200Ω/0 - 2000ΩEarth Voltage [50,60Hz]: 0 - 200V ACAccuracyEarth Resistance: ±2%rdg±0.1Ω (20Ωrange)±2%rdg±3dgt (200Ω/2000Ωrange)Earth Voltage: ±1%rdg±4dgtOverload protectionEarth Resistance: 280V AC for 10 secondsacross 2 of the 3 terminalsEarth Voltage: 300V AC for 1 minuteApplicable standardsIEC 60529 IP54Safety StandardIEC 61010-1 CAT III 300V Pollution Degree 2, IEC 61557Power sourceR6 (AA) (1.5V) × 6Dimensions105(L) × 158(W) × 70(D)mmWeight550g approx.Included Accessories7095A (Earth resistance test leads) × 1set(red-20m, yellow-10m, green-5m)8032 (Auxiliary earth spikes) × 1set7127A (Simplified measurement probe) × 1setR6 (AA) × 69121 (Shoulder strap)Instruction ManualCarrying case : 9084(Carrying case[Soft]:4105A only)       : 9165(Carrying case[Hard]:4105A-H only)Optional Accessories7100A (Precision measurement cord set)Accessories/Optional Accessories /Related ProductsMODEL 7095AMODEL 8032MODEL 7127AMODEL 9165MODEL 7100AMODEL 9121[...]



Kyoritsu Indonesia - KEW 4300

Tue, 06 Feb 2018 08:11:00 +0000

Kyoritsu Indonesia - Earth TestersKEW 4300 New Simplified Earth TesterKEW 4300 is simplified earth resistance tester (based on 2-pole method) that can be used for various distribution lines and electrical appliances and it also can measure AC/DC voltage. (As for AC Voltages, true rms values can be obtained.)• 200/2000Ω (2 ranges): auto-ranging.• Warning buzzer triggered at 100Ω or less.• LED lights up when a large earth voltage is detected.• Live circuit warning when 30V or higher voltage is detected. (KEW 4300 detects voltage even when measuring resistances.)• LED light for illuminating measurement points.(It turns on/off automatically in relation to the ambient brightness.)• Small test current (max 2mA) not triggering RCD. Earth resistance ranges200.0/2000Ω (Auto ranging)±3%rdg±5dgtVoltage rangesAC: 5.0 - 300.0V (45 - 65Hz)±1%rdg±4dgtDC: ±5.0 - 300.0V±1%rdg±8dgtApplicable standardsIEC 61010-1 CAT III 300V pollution degree 2IEC 61010-031, 61557-1, -5IEC 61326-1, 2-2, IEC 60529 (IP40)Power sourceLR6(AA)(1.5V) × 2pcsDimensions232(L) × 51(W) × 42(D)mmWeight220g approx. (including battery)Included Accessories7248 (Test lead with Alligator clip and Flat test probe)8072 (CAT II Standard prod)8253 (CAT III Standard prod)8017 (Extension prod long)9161 (Carrying case)Instruction manual, LR6 (AA) × 2[...]



Kyoritsu Indonesia - KEW 4106

Tue, 06 Feb 2018 08:08:00 +0000

Kyoritsu Indonesia - Earth Resistance & Resistivity TesterKEW 4106 Earth Resistance & Resistivity Tester• High test current up to 80mA yielding resolution of 0.001Ω on 2Ω range.• Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements.• Automatic and Manual selection of the Test Current Frequency in four bands (94/105/111/128Hz). In Automatic mode, KEW 4106 will select the most suitable Frequency.• Several sub-results can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference (noise), Residual Resistance Rk, etc.• Warning for excessive noise and high Auxiliary Earth Spikes resistance.• Large Graphic Display with backlight for readings in poorly illuminated areas.• Up to 800 measurement results can be saved in the memory and recalled on the display.• The stored results can be transferred to a PC using the "KEW Report" software and a USB adaptor (Model 8212-USB) which are included.• Robust design with IP54 protection. FunctionRangeResolutionMeasuring rangeAccuracyEarth resistanceRe(Rg atρ measurement)2Ω0.001Ω0.03 - 2.099Ω±2%rdg±0.03Ω20Ω0.01Ω0.03 - 20.99Ω±2%rdg±5dgt (*1)200Ω0.1Ω0.3 - 209.9Ω2000Ω1Ω3 - 2099Ω20kΩ10Ω0.03k - 20.99kΩ200kΩ100Ω0.3k - 209.9kΩAuxiliary earth resistanceRh, Rs8% of Re+Rh+RsEarth resistivityρ2Ω0.1Ω·mm - 1Ω·mAutoranging0.2 - 395.6Ω·mρ=2×π×a×Rg (*2)20Ω0.2 - 3956Ω·m200Ω20 - 39.56kΩ·m2000Ω0.2 - 395.6kΩ·m20kΩ2.0 - 1999kΩ·m200kΩSeries interference voltageUst (A.C only) (*3)50V0.1V0 - 50.9Vrms±2%rdg±2dgt (50/60Hz)±3%rdg±2dgt (40 - 500Hz)FrequencyFstAutoranging0.1Hz1Hz40Hz - 500Hz±1%rdg±2dgtMeasuring methodEarth resistance: Fall-of-potential method(currents and voltages measured via the Probes)Measurement method of Earth Resistivity (ρ): Wenner 4-pole methodSeries interference voltage (earth voltage)RMS Rectifier (between the E-S Terminals)Memory capacity800 dataCommunication InterfaceModel 8212-USB Optical AdaptorLCDDot-matrix 192×64 monochromeOver-range Indication"OL"Overload Protectionbetween E-S(P) and between E-H(C) terminals AC280V / 10 sec.Applicable standardsIEC 61010-1 CAT III 300V, CAT IV 150V Pollution degree 2IEC 61010-031, IEC 61557-1, 5, IEC 61326-1 (EMC), IEC 60529 (IP54)Power sourceDC12V : sizeAA manganese dry battery (R6) × 8(Auto power off: approx. 5 minutes)Dimensions167(L) × 185(W) × 89(D) mmWeightapprox. 900g (including batteries)Accessories7229A (Earth precision measurement),7238A (Simplified measurement test leads),8032 (Auxiliary earth spikes [2 spiks/set])×2 sets (4 spikes in total),8200-04 (Cord reel [4 pcs])×1 set,8212-USB (USB adaptor with "KEW Report(Software)"),9121 (Shoulder strap),9125 (Carrying case),R6 × 8, Instruction manual, Calibration certificateOptional8212-RS232C (RS232C adaptor with "KEW Report(Software)")[...]



Kyoritsu Indonesia - KEW 4202

Tue, 06 Feb 2018 08:06:00 +0000

Kyoritsu Indonesia - Earth Clamp TestersKEW 4202 Various useful functions are available on Android devices using Bluetooth communication• Real time measurements can be transferred, shown and saved on Android device (up to 100 measurements)• Saved data includes measurement, GPS location and date & time Easy to check on map "When" and "Where" the measurement was made• Comparator function on Android device informs when the measured value is lower/higher than the preset valueEarth /Ground resistance and Leakage current measurement functions• The earth resistance from 0.05 to 1500 Ω can be measured without the auxiliary earth spikes in multi-earthing systems• True RMS leakage or phase current readings from 0.1mA to 30.0A provides vital additional information in earthing networks• Filter function offers increased immunity to electrical noise and a Noise mark appears in excessively high noisy environments Free Android software "KEW smart 4202"is available on "Google Play Store"(*)• Supporting Android ver. 3.0 - 6.0• WVGA (800 × 480) resolution or higher• GPS function(*)Please search "KEW Smart" in Google Play Store.Communication charge may be incurred separately to download application.Earth resistance Auto range20.00/200.00/1500Ω±1.5%±0.05Ω(0.00 - 20.99Ω)±2%±0.5Ω(16.0 - 99.9Ω)±3%±2Ω(100.0 - 209.9Ω)±5%±5Ω(160 - 399Ω)±10%±10Ω(400 - 599Ω)AC current (50Hz/60Hz) Auto rangeValues are displayed, but accuracy isn't guaranted(600 - 1580Ω)100.0/1000mA/10.00/30.0A±2%±0.7mA(0.0 - 104.9mA)±2%(80mA - 31.5A)Operating indicationEarth resistance function :Constant voltage injectionCurrent detection (Frequency : Approx.2400Hz)Dual IntegrationAC current function : Successive approximationOver-range indication"OL"is displayed when input exceeds the upper limit of a measuring rangeResponse timeApprox. 7 seconds (Earth resistance)Approx. 2 seconds (AC current)Sample rateApprox. 1 times per secondCommunication InterfaceBluetooth Ver2.1 + EDR Class2Current consumptionApprox. 50mA (max.100mA)Measurement timeApprox.5 hours (when R6 is used) Approx. 21 hours (when LR6 is used)Auto power-offTurns power off about 10 minutes after the last button operation.Conductor sizeApprox.Ø32mmApplicable standardsIEC 61010-1 CAT Ⅳ 300V Pollution degree2IEC 61010-2-032, IEC 61326 (EMC)Power sourceDC6V : R6(sizeAA manganese battery) x 4or LR6 (sizeAA alkaline battery) x 4Dimensions246(L)×120(W)×54(D)mmWeightApprox. 780g (including batteries)Included AccessoriesLR6 x 4, Instruction manual8304 (Resister for operation check)9167 (Carrying case[Hard])Accessories/Optional Accessories /Related ProductsMODEL 8304MODEL 9167[...]



Kyoritsu Indonesia - KEW 3123A

Tue, 06 Feb 2018 07:35:00 +0000

Kyoritsu Indonesia - High Voltage Insulation TestersKEW 3123A • Rugged design with a hard carrying case for field use• Detachable High Voltage Line probe• Automatic ranges, high and low scales, indicated by different LED's• Drip proof Insulation ResistanceDC Test Voltage5000/10000VMeasuring ranges(automatic change)5GΩ/200GΩ (Auto-ranging) (5000V)10GΩ/400GΩ (Auto-ranging) (10000V)First effective measuring range0.2 - 100GΩ (5000V)0.4 - 200GΩ (10000V)Accuracy± 5% rdgOther ranges accuracy±10% rdg or 0.5% of scale lengthGeneralPower sourceR6 (AA) (1.5V) × 8Dimensions200 (L) × 140 (W) × 80 (D) mmWeightapprox. 1kgIncluded Accessories7165A (Line probe) (3m)7224A (Earth cord) (1.5m)7225A (Guard code) (1.5m)8019 (Hook type prod)9158 (Hard case)R6 (AA) × 8Instruction manualOptional Accessories7168A(Line probe with aligator clip)8324 (Adaptor for recorder)7253 (Longer Line probe with alligator clip) (15m)Accessories/Optional Accessories /Related ProductsMODEL 7165AMODEL 7224AMODEL 7225AMODEL 8019MODEL 9158MODEL 7168AMODEL 8324MODEL 7253[...]



Kyoritsu Indonesia - KEW 3431

Tue, 06 Feb 2018 07:25:00 +0000

Kyoritsu Indonesia - Analogue Insulation TestersKEW 3431  • Extremely compact and lightweight design.• Automatic sensor turns the illuminated scale and LED spot light ON/OFF, useful in dimly lit location.• Standard accessories include test probe with remote control switch and protective carry case.• Live circuit warning with buzzer and flashing LED. Insulation resistanceTest voltage 250V500V1000VMax. effective scale value200MΩ2000MΩMid-scale value5MΩ50MΩFirst effective measuring ranges0.1MΩ - 100MΩ1MΩ - 1000MΩAccuracy±5% of indicated valueSecond effective measuring rangesMeasuring ranges other than above, 0 and ∞Accuracy±10% of indicated valueLED insulation state indicator indicating result by red / green color0.25MΩ0.5MΩ1MΩVoltage measurementVoltage rangeAC 600V [45 - 65Hz]/DC 600VAccuracy±5% of full scale valueApplicable StandardsIEC 61010-1, 2-030 CAT Ⅲ 600V, IEC 61557-1, -2IEC 61010-031, IEC 61326(EMC), EN 50581(RoHS)Power sourceLR6/R6(AA)(1.5V) × 4Dimensions / Weight97(L) × 156(W) × 46(D)mm / 430g approx.Included Accessories7260(Test lead with remote control switch),7261(Test lead with alligator clip), 9173(Carrying case),8017A(Extension prod long), 9121(Shoulder strap),LR6(AA) × 4, Instruction manualOptional Accessories7243(L-shaped probe), 8016(Hook type prod)Accessories/Optional Accessories /Related ProductsMODEL 7243MODEL 7260MODEL 7261MODEL 8016MODEL 8017AMODEL 9121MODEL 9173[...]



Kyoritsu Indonesia - KEW 3122B

Tue, 06 Feb 2018 07:14:00 +0000

Kyoritsu Indonesia - High Voltage Insulation TestersKEW 3122B • Extremely easy and simple operation• Automatic ranges, indicated by individual LED's• Newly-designed alligator clip• It comes with a tough hard case• Safety Standard IEC 61010-1 CAT IV 300V / CAT III 600V(Photo: 3121B) Insulation ResistanceTest voltage5000VMeasuring ranges5GΩ/200GΩ (Auto-ranging)Accuracy0.2 - 100GΩ: ±5%rdg0 - 0.2GΩ, 100GΩ - ∞:±10%rdg or 0.5% of scale lengthGeneralApplicable standardsIEC 61010-1, 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600VPollution degree 2, IEC 61010-031, IEC 61326-1, 2-2Power sourceDC12V : LR14/R14 × 8pcsDimensions177 (L) × 226 (W) × 100 (D) mm300 (L) × 315 (W) × 125 (D) mm (Hard case)Weight1.7kg approx.Included Accessories7165A (Line probe: 3m)7264 (Earth cord: 3m)7265 (Guard cord: 3m)8019 (Hook type prod)9183 (Carrying case[Hard])LR14 (Alkaline battery size C) × 8Instruction manualOptional Accessories7168A (Line probe with aligator clip: 3m)7253 (Longer line probe with alligator clip: 15m)8324 (Adaptor for recorder)Accessories/Optional Accessories /Related ProductsMODEL 7165AMODEL 7264MODEL 7265MODEL 8019MODEL 7168AMODEL 7253MODEL 8324MODEL 9183[...]



Kyoritsu Indonesia - KEW 3125A

Tue, 06 Feb 2018 07:07:00 +0000

Kyoritsu Indonesia - High Voltage Insulation TestersKEW 3125A  • Insulation Resistance up to 1TΩ• Short-Circuit Current up to 1.5mA• Wide Test Voltage from 250V to 5000V• Diagnosis Function of PI and DAR• Newly-designed alligator clip• It comes with a tough hard case• Filter function reduces noise interference for obtaining stable measurement• Large display with Bar Graph indication and backlight• Live voltage warning• Safety standard IEC 61010-1 CAT IV 300V / CAT III 600V Insulation resistanceRated voltage250V500V1000V2500V5000VAccuracy0.0 - 100.0MΩ 0.0 - 99.9MΩ80 - 1000M Ω  0.0 - 99.9MΩ80 - 999MΩ0.80 - 2.00G  Ω 0.0 - 99.9MΩ 80 - 999MΩ 0.80 - 9.99GΩ 8.0 - 100.0GΩ0.0 - 99.9MΩ80 - 999MΩ0.80 - 9.99GΩ8.0 - 99.9GΩ80 - 1000GΩ±5%rdg±3dgt±5%rdg±3dgt±5%rdg±3dgt±5%rdg±3dgt±5%rdg±3dgt±20%rdg(100GΩ or more)Short circuit current1.5mAOutput voltageAccuracy±10%-10 - +20%0 - +20%Monitor±10%rdg±20VVoltage measurementMeasuring rangeAC: 30 - 600V (50/60Hz), DC: ±30 - ±600VAccuracy±2%rdg±3dgtGeneralApplicable standardsIEC 61010-1, 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2,IEC 61010-031, IEC 61326-1, 2-2Power sourceDC12V : LR14/R14 × 8pcsDimensions177 (L) × 226 (W) × 100 (D) mm300 (L) × 315 (W) × 125 (D) mm (Hard case)Weight3125A: 1.9kg approx. (including batteries)4kg approx. (including accessories)Included Accessories7165A (Line probe: 3m), 7264 (Earth cord: 3m), 7265 (Guard cord: 3m),8019 (Hook type prod), 9180 (3025A Hard case), 9181 (3125A Hard case),LR14 (Alkaline battery size C) × 8, Instruction manualOptional Accessories7168A (Line probe with alligator clip: 3m),7253 (Longer line probe with alligator clip: 15m),8302 (Adaptor for recorder)Accessories/Optional Accessories /Related ProductsMODEL 7165AMODEL 7264MODEL 7265MODEL 8019MODEL 9181MODEL 7168AMODEL 7253MODEL 8302[...]



Kyoritsu Indonesia - Power Quality Analyzer KEW 6315

Tue, 06 Feb 2018 06:36:00 +0000

Kyoritsu Indonesia - Power Quality AnalyzerKEW 6315 • Simultaneous Power & Power quality measurements• Helpful support functions• Measurement with high accuracy• Remote monitoring on PC and Android device• Various Clamp Current Sensors• Energy consumption check on site• IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V   Simultaneous Power & Power quality measurements Power/ Harmonics/ Waveform/ Power quality are recorded at all CHs. (Voltage: 3ch, Current 4ch) Helpful support functions Quick Start Guide, Wiring check and Sensor detection for easy and reliable measurementMeasurement with high accuracy Guaranteed accuracy:±0.3%rdg (energy),±0.2%rdg (voltage/ current) Complies with the International Standard IEC 61000-4-30 Class S and the European Standard EN50160Remote monitoring on PC and Android device Remote checking of measurement in real-time is possible via Bluetooth communication.Recorded data can be saved in the supplied SD card.EN50160 report can be generated after survey by PC software.Various Clamp Current Sensors Various types of clamp and flexible sensors are available:from 1000mA Range up to 3000A Range and Earth leakage measurementsEnergy consumption check on siteTrend and demand graphs for easy recognition.TFT color display with high resolution.IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000VFree Android software "KEW smart 6315" is available on "Google Play Store"•Supporting Android ver. 3.0 - 6.0•WVGA (800 × 480) resolution or higherPlease search "KEW Smart" in Google Play Store.Communication charge may be incurred separately to download application.Power Quality AnalyzerWiring connections1P2W, 1P3W, 3P3W, 3P4WMeasurements and parametersVoltage, Current, Frequency, Active power, Reactive power, Apparent power,Active energy, Reactive energy, Apparent energy, Power factor (cos θ),Neutral current, Demand, Harmonics, Quality (Swell/Dip/Interruption, Transients/Over voltage, Inrush current, Unbalance rate),Capacitance calculation for PF correction unit, FlickerVoltage (RMS)Range600.0 / 1000VAccuracy±0.2%rdg±0.2%f.s. (sine wave, 40 - 70Hz)Allowable input1 - 120% of each range (rms). 200% of each range (peak)Display range0.15 - 130% of each rangeCrest factor3 or lessSampling speed of Voltage transient24µsCurrent (RMS)Range8128 ( 50A type ) : 5000mA / 50.00A / AUTO8127 ( 100A type ) : 10.00 / 100.0A / AUTO8126 ( 200A type ) : 20.00 / 200.0A / AUTO8125 ( 500A type ) : 50.00 / 500.0A / AUTO8124/8130 ( 1000A type ) : 100.0 / 1000A / AUTO8146/8147/8148 ( 10A type ) : 1000mA / 10.00A / AUTO8129 ( 3000A type ) : 300.0 / 1000 / 3000AAccuracy±0.2%rdg±0.2%f.s. + accuracy of clamp sensor (sine wave, 40 - 70Hz)Allowable input1 - 110% of each range (rms). 200% of each range (peak)Display range0.15 - 130% of each rangeCrest factor3 or lessActive powerAccuracy±0.3%rdg±0.2%f.s. + accuracy of clamp sensor(power factor 1, sine wave, 40 - 70Hz)Influence of power factor±1.0%rdg (reading at power factor 0.5 against power factor 1)Frequency meter range40 - 70HzPower supply (AC Line)AC100 - 240V / 50 - 60Hz / 7VA maxPower supply (DC battery)Alcaline size AA battery LR6 or Ni-MH (HR-15-51) × 6Battery life approx. 3h (LR6, Backlight OFF)Internal memoryFLASH memory (4MB)PC card interfaceSD card (2GB)PC communication interfaceUSB Ver2.0, Bluetooth Ver2.1 + EDR Class2Display320 × 240 (RGB) Pixel, 3.5inch color TFT displayDisplay update period1 sec General Applicable standards IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V Pollution degree 2IEC 61010-2-030, IEC 61010-031, IEC 61326, EN 50160IEC 61000-4-30 Class S, IEC 61000-4-15, IEC 61000-4-7 Temperature and humidity range 23±5ºC, less than 85% RH (without condensation) Operating temperature & humidity range [...]



Kyoritsu Indonesia - Power Meter KEW 6305

Tue, 06 Feb 2018 06:30:00 +0000

Kyoritsu Indonesia - Power MeterKEW 6305 • Comprehensive real-time monitoring, recording and analysis of single and 3-phase systems• Voltage, Current, Power Factor and Frequency measurements• Power analysis (Active, Apparent and Reactive power)• Energy analysis (Active, Apparent and Reactive power)• Active power accuracy: ±0.3%rdg±0.2%f.s.• Automatic wiring check function to prevent incorrect connections• Large memory capability (2GB) using built-in SD card interface• Real time & remote measurements using Android application• synchronous measurements between two units of KEW 6305• Wide selection of clamp sensors allow measurements from 0.1A to 3000A• The instrument automatically recognizes what kind of clamp sensor is connected to it• Windows software for data analysis and setting via USB port or Bluetooth   Free Android software "KEW smart 6305" is available on "Google Play Store"•Supporting Android ver. 3.0 - 6.0•WVGA (800 × 480) resolution or higherPlease search "KEW Smart" in Google Play Store.Communication charge may be incurred separately to download application. Wiring connections 1P2W, 1P3W, 3P3W, 3P3W3A, 3P4W Measurements Voltage, Current, Frequency, Active power Parameters Apparent power, Reactive power, Active energy, Apparent energy,Reactive energy, Power factor (cos θ), Neutral current Voltage range[RMS] 150.0 / 300.0 / 600.0V Voltage accuracy ±0.2%rdg±0.2%f.s. (sine wave, 45 - 65Hz) Current range[RMS] 8128 ( 50A type ) : 1.000 / 5.000 / 10.00 / 25.00 / 50.00A / auto8127 ( 100A type ) : 2.000 / 10.00 / 20.00 / 50.00 / 100.0A / auto8126 ( 200A type ) : 4.000 / 20.00 / 40.00 / 100.0 / 200.0A / auto8125 ( 500A type ) : 10.00 / 50.00 / 100.0 / 250.0 / 500.0A / auto8124 ( 1000A type ) : 50.00 / 100.0 / 200.0 / 500.0 / 1000A / auto8130 ( 1000A type ) : 50.00 / 100.0 / 200.0 / 500.0 / 1000A / auto8129 ( 3000A type ) : 300.0 / 1000 / 3000A Current accuracy ±0.2%rdg±0.2%f.s. + Accuracy of Clamp sensor (sine wave, 45 - 65Hz)(*) +1%f.s. at the lowest range Display range 5 - 130% of each range(Voltage)1 - 130% of each range(Current) Crest factor Voltage: up to 2.5, Current: up to 3.0 (with 90% fs or less) Allowable input ±0.3%rdg±0.2%f.s. + Accuracy of Clamp sensor(*) +1%f.s. when the lowest current ranges is selected. Effect of power factor Active power: ±1.0%rdg cos θ=±0.5 (PF=1) Frequency meter range 40.0 - 70.0Hz Frequency meter accuracy ±3dgt Accuracy precondition PF=1, Sine wave, 45 - 65Hz, 23ºC±5ºC Display update period 1 second Applicable standards IEC 61010-1 CAT III 600V Operating temperature & humidity range 0 - +50ºC, less than 85%RH (without condensation) Storage temperature & humidity range -20 - +60ºC, less than 85%RH (without condensation) Power supply (AC Line) AC100 - 240V±10% (50/60Hz) Power supply (DC battery) LR6 or Ni-MH (HR-15-51) ×6 (Battery charger not included),Battery life approx. 15h (LR6) Power consumption 10VA (max.) communication interface USB, Bluetooth PC card interface SD card (2GB) Dimensions 175(L)×120(W)×65(D) mm Weight Approx. 800g (including batteries) Included Accessories 7141B (Voltage test lead set: 4pcs)7148 (USB cable)7170 (Power cord)9125 (Carrying case)8326-02 (SD card 2GB)KEW WINDOWS (PC Software)Battery (LR6)×6Quick manual Opt[...]



Kyoritsu Indonesia - Loggers KEW 5020

Tue, 06 Feb 2018 06:25:00 +0000

Kyoritsu Indonesia - LoggersKEW 5020 3 channel inputs for the simultaneous recording of Leakage Current , Load Current and Voltage• Power Quality analysis• Large capacity for storing 60,000 data points• Lowpass Filter will filter out the harmonics• LED flickers when the preset current/voltage value is exceeded• CALL:Confirmation of recorded data• Selection of One-time mode or Endless mode• Non Volatile Memory• Battery power indicator• The userfriendly PC software "KEW LOG Soft 2" is supplied• Continuous measuring time:Approx. 10 days (Alkaline Battery)   3 channel inputs for the simultaneous recording of Leakage Current, Load Current and VoltageLarge Capacity for storing 60,000 data points 60,000 data points can be recorded when 1ch is used, and when all the three channels are used, 20,000 data points per channel can be recordedLowpass Filter will filter out the harmonics (Cutoff Frequency = Approx. 160Hz)LED flickers when the preset current / voltage value is exceededCALL: Confirmation of recorded data The following can be displayed: number of recorded data points, (max+ min+ peak) value for each channel complete with time/date information in the Normal recording mode. (Detected values (i.e. when values are outside preset limits ) can be displayed in other recording modes)RECALL: The last 10 recorded data points including time/date can be recalled on the logger displaySelection of One-time mode or Endless mode One-time on: Recording will stop when memory is used upOne-time off: Overwrite the old data, and store the latest dataNon Volatile MemoryRecorded data will be retained even if the batteries are exhausted or replaced due to the presence of a nonvolatile memory (guaranteed for 10 years)Battery power indicatorIndicates battery voltage in 4-levels(It is possible to use the logger for a further approx. 24 hours even after the warming symbol is flashing)The userfriendly PC software "KEW LOG Soft 2" is suppliedSupplied with the user friendly software "KEW LOG Soft 2". This permits editing, analysis and graphical display of data.The recorded data is downloadable onto a PC via USB cable.Variation of the measured voltage and current data can be confirmed simultaneously on the PC display monitor. (only on KEW 5020)Simplified Power Integration(The "KEW LOG Soft 2" uses current and voltage recorded to calculate the integral power consumption)Continuous measuring time: Approx. 10 days (Alkaline Battery)Normal Recording Mode(AC 50/60Hz, Sine wave, Input: 10% or more of the range at CH1)RangeRMS Accuracy100.0mA±2.0%rdg±0.9%f.s.+ Accuracy of SensorOther ranges±1.5%rdg±0.7%f.s.+ Accuracy of SensorCrest Factor2.5 or less: RMS accuracy (sine) + 2%rdg + 1%f.s.*Max, Min and Instant Peak values in Normal Recording mode are just reference values:their accuracies aren't guaranteed.Trigger Recording Mode (AC 50/60Hz sine wave)RangeAccuracy100.0mA±3.5%rdg±2.2%f.s.+ Accuracy of SensorOther ranges±3.0%rdg±2.0%f.s.+ Accuracy of SensorCapture Recording ModeRangeAccuracy100.0mA±3.0%rdg±1.7%f.s.+ Accuracy of SensorOther ranges±2.5%rdg±1.5%f.s.+ Accuracy of Sensor Recording mode Normal, Trigger, Capture, Power Quality Analysis Operating system Successive Approximation(CH1 single synchronized sampling) Rated max. working voltage AC 9.9Vrms, 14V peak value Number of input channel 3ch Measuring method True RMS RMS measuring interval approx. 100ms Sampling interval Normal/Trigger mode : approx. 1.65ms/CH Capture mode : approx. 0.55ms (waveform: at every 1.1ms) P.Q.A. mode : approx. 0.55ms Low battery warning Battery mark display (in 4 level[...]



Kyoritsu Indonesia - Loggers KEW 5010

Tue, 06 Feb 2018 06:18:00 +0000

Kyoritsu Indonesia - LoggersKEW 5010 3 channel inputs for the simultaneous recording of Leakage Current and Load Current• Large capacity for storing 60,000 data points• Lowpass Filter will filter out the harmonics• LED flickers when the preset current value is exceeded• CALL:Confirmation of recorded data• Selection of One-time mode or Endless mode• Non Volatile Memory• Battery power indicator• The userfriendly PC software "KEW LOG Soft 2" is supplied• Continuous measuring time:Approx. 10 days (Alkaline Battery)   3 channel inputs for the simultaneous recording of Leakage Current, Load Current and VoltageLarge Capacity for storing 60,000 data points 60,000 data points can be recorded when 1ch is used, and when all the three channels are used, 20,000 data points per channel can be recordedLowpass Filter will filter out the harmonics (Cutoff Frequency = Approx. 160Hz)LED flickers when the preset current value is exceededCALL: Confirmation of recorded data The following can be displayed: number of recorded data points, (max+ min+ peak) value for each channel complete with time/date information in the Normal recording mode. (Detected values (i.e. when values are outside preset limits ) can be displayed in other recording modes)RECALL: The last 10 recorded data points including time/date can be recalled on the logger displaySelection of One-time mode or Endless mode One-time on: Recording will stop when memory is used upOne-time off: Overwrite the old data, and store the latest dataNon Volatile MemoryRecorded data will be retained even if the batteries are exhausted or replaced due to the presence of a nonvolatile memory (guaranteed for 10 years)Battery power indicatorIndicates battery voltage in 4-levels(It is possible to use the logger for a further approx. 24 hours even after the warming symbol is flashing)The userfriendly PC software "KEW LOG Soft 2" is suppliedSupplied with the user friendly software "KEW LOG Soft 2". This permits editing, analysis and graphical display of data.The recorded data is downloadable onto a PC via USB cable.Continuous measuring time: Approx. 10 days (Alkaline Battery)Normal Recording Mode(AC 50/60Hz, Sine wave, Input: 10% or more of the range at CH1)RangeRMS Accuracy100.0mA±2.0%rdg±0.9%f.s.+ Accuracy of SensorOther ranges±1.5%rdg±0.7%f.s.+ Accuracy of SensorCrest Factor2.5 or less: RMS accuracy (sine) + 2%rdg + 1%f.s.*Max, Min and Instant Peak values in Normal Recording mode are just reference values:their accuracies aren't guaranteed.Trigger Recording Mode (AC 50/60Hz sine wave)RangeAccuracy100.0mA±3.5%rdg±2.2%f.s.+ Accuracy of SensorOther ranges±3.0%rdg±2.0%f.s.+ Accuracy of SensorCapture Recording ModeRangeAccuracy100.0mA±3.0%rdg±1.7%f.s.+ Accuracy of SensorOther ranges±2.5%rdg±1.5%f.s.+ Accuracy of Sensor Recording mode Normal, Trigger, Capture Operating system Successive Approximation(CH1 single synchronized sampling) Rated max. working voltage AC 9.9Vrms, 14V peak value Number of input channel 3ch Measuring method True RMS RMS measuring interval approx. 100ms Sampling interval Normal/Trigger mode : approx. 1.65ms/CH Capture mode : approx. 0.55ms (waveform: at every 1.1ms) Low battery warning Battery mark display (in 4 levels) Over-range indication "OL" mark is displayed when exceeding the measuring range Auto power off Power-off function operates automatically after a switch remains for 3min. (when recording is stopped) Possible measurement time Approx. 10 days (with alkaline LR6 batteries) [...]



Kyoritsu Indonesia - AC Digital Clamp Meters KEW 2127R

Tue, 06 Feb 2018 05:01:00 +0000

Kyoritsu Indonesia - AC Digital Clamp MetersKEW 2127R • 1000A AC Clamp Meter, AC60/600/1000A Auto Range• True-RMS• Peak Hold for inrush current• 6000 counts display with Backlight• ø33mm Tear Drop shaped jaw easy to use in tight places• Double molding gives comfortable feeling• Safety standerd IEC 61010-1, CAT Ⅳ 300V/ CAT Ⅲ 600V   AC A 60.00/600.0/1000A (Auto-ranging)±1.5%rdg±4dgt [45 - 65Hz] ±2.0%rdg±5dgt [40 - 1kHz] AC V 60.00/600.0V (Auto-ranging)±1.0%rdg±2dgt [45 - 65Hz] (600V)±1.5%rdg±4dgt [40 - 1kHz] (60/600V) DC V 60.00/600.0V (Auto-ranging)±1.0%rdg±3dgt (60V) ±1.2%rdg±3dgt (600V) Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/40.00MΩ(Auto-ranging)±1.0%rdg±5dgt (600Ω) ±2.0%rdg±3dgt (6/60/600kΩ)±3.0%rdg±3dgt (6MΩ) ±5.0%rdg±3dgt (40MΩ) Continuity buzzer 600Ω (Buzzer sounds below 90Ω) Capacitance test 1.000/10.00/100.0μF ±3.0%rdg±15dgt(1μF) ±3.0%rdg±10dgt(10/100μF) Diode test 2.000V ±4%rdg±5dgt Open-circuit voltage:<3.5V Hz 999.9Hz/9.999kHz (Auto-ranging) ±0.1%rdg±3dgt(Input sensitivity Current:more than 4A Voltage:more than 2V) Conductor size φ33mm max. Applicable standards IEC 61010-1 CAT Ⅳ 300V, CAT Ⅲ 600V Pollution degree 2IEC 61010-031, IEC 61010-2-032, IEC 61010-2-033,IEC 61326-2-2(EMC), IEC 60529 IP40, EN 50581(RoHS) Power source R03/LR03(AAA)(1.5V)x2 Continuous measuring time approx. 170 hours(when R03 is used)(NCV_LED, Backlight:off)(Auto power save : approx.10 minutes) Dimensions 204(L) × 81(W) × 36(D)mm Weight 230g Approx. (including batteries) Included Accessories 7066A (Test leads), 9079 (Carrying case), R03(AAA)×2,Instruction manual Accessories/Optional Accessories /Related ProductsMODEL 7066AMODEL 9079[...]



Kyoritsu Indonesia - KEW 2500 DC Milliamp Clamp Meter

Tue, 06 Feb 2018 04:57:00 +0000

Kyoritsu Indonesia DC Milliamp Clamp Meter

KEW 2500

(image)
(image)
• 0.01mA resolution for DC current
• Top class measurement 0.2% accuracy
• Ø6mm clamp jaw easy to use in tight places
• Measurement from 0.01mA to 120.0mA
• Dual display with backlight shows both mA measurement and percent of 4-20 mA span
• Spotlight for illuminating measurement point
• Analog output terminal for recorder connection
(image) (image) (image) (image) (image) (image)  
DC A 20/100mA (Auto ranging)
±0.2%rdg±5dgt (0.00mA - 21.49mA)
±1.0%rdg±5dgt (21.0mA - 120.0mA)
Conductor size Ø6mm max.
Analog output Recorder: DC 1000mV against DC 100mA
Applicable standards IEC 61010-1, Pollution degree 2
IEC 61010-2-032, IEC 61326-1(EMC)
IEC 60529 IP40, EN50581(RoHS)
Operating temperature & humidity range -10 - +50ºC < 85%
Storage temperature & humidity range -20 - +60ºC < 85%
Power source R6/LR6 (AA) (1.5V) × 4
Dimensions 111(L) × 61(W) × 40(D)mm : Display unit
104(L) × 34(W) × 20(D)mm : Sensor
700mm : Sensor cable
Weight Approx. 290g (including batteries)
Included Accessories 9096 (Carrying case), LR6 (AA) × 4,
Instruction Manual
Optional Accessories 7256 (Output cord)

Accessories/Optional Accessories /Related Products

  • (image)



Kyoritsu Indonesia - KEW 2510

Tue, 06 Feb 2018 04:42:00 +0000

Kyoritsu Indonesia - DC Milliamp Clamp LoggerKEW 2510 • Measures 4 to 20 mA instrumentation and process signals without breaking the loop• Memory function stores up to 192000 data useful for monitoring the signals over time and fault finding• Transfer data to PC via Bluetooth• Top class measurement 0.2% accuracy• ∅6mm clamp jaw easy to use in tight places• LED light for illuminating the measurement spot• Analog output terminal to allow the connection to a recorder or a digital multimeter   AC A 20/100mA(Auto ranging)±0.2%rdg±5dgt (0.00mA - 21.49mA)±1.0%rdg±5dgt (21.0mA - 120.0mA) Conductor size φ6mm max. Analog output Recorder: DC1000mV against DC100mA Applicable standards IEC 61010-1, Pollution degree 2IEC 61010-2-032, IEC 61326-1(EMC)IEC 60529 IP40, EN50581(RoHS) Operating temperature & humidity range -10 - +50℃ <85% Storage temperature & humidity range -20 - +60℃ <85% Power source R6/LR6(AA) (1.5V) x4 (Alkaline LR6 is recommended.)External supply (AC adapter MODEL8320) communication interface Bluetooth Ver2.1+EDR Class2 Dimensions / Weight 111(L)x61(W)x46(D)mm : Display unit104(L)x33(W)x20(D)mm : Sensor700mm : Sensor CableApprox. 310g(including batteries) Included Accessories 8320(AC adapter), KEW Windows for 2510(Software)9096(Carrying case), LR6(AA)x4, Instruction manualSoftware installation manual Optional Accessories 7256(Output cord) Accessories/Optional Accessories /Related ProductsMODEL 7256MODEL 8320MODEL 9096[...]



Kyoritsu Indonesia - Kyoritsu KEWMATE 2012R

Tue, 06 Feb 2018 03:54:00 +0000

Kyoritsu Indonesia - Digital Multimeter with AC/DC Clamp SensorKEWMATE 2012R • Innovative Multimeters with current measurements up to 120A AC/DC• Unique Open Jaw technology for AC/DC current measurements• Very compact and as reliable as a tradictional full size multimeter   DC V 600.0mV/6.000/60.00/600.0V (Input impedance: approx. 10MΩ)±1.0%rdg±3dgt AC V 6.000/60.00/600.0V (Input impedance: approx.10MΩ)±1.5%rdg±5dgt (45 - 400Hz) DC A 60.00/120.0A±2.0%rdg±8dgt (60A)±2.0%rdg±5dgt (120A) AC A 60.00/120.0A±2.0%rdg±5dgt (45 - 65Hz) Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ±1.0%rdg±5dgt (600Ω/6/60/600kΩ)±2.0%rdg±5dgt (6MΩ)±3.0%rdg±5dgt (60MΩ) Continuity buzzer Buzzer sounds below 35±25Ω Diode test 2V±3.0%rdg±5dgtOpen-loop voltage: approx. 2.7V Capacitance 400.0nF/4.000/40.00µF±2.5%rdg±10dgt Frequency (AC A)100/400Hz ±0.2%rdg±2dgt (100Hz) ±0.1%rdg±1dgt (400Hz) (DC A)100/1000Hz/10/100/300.0kHz ±0.2%rdg±2dgt (100Hz)±0.1%rdg±1dgt (1000Hz/10/100/300.0kHz) (Input sensitivityCurrent: more than 6AVoltage: more than 6V [- 10kHz]/more than 20V [10k - 300kHz]) Conductor size Ø12mm max. Applicable standards IEC 61010-1 CAT III 300V, CAT II 600V Pollution degree 2IEC 61010-031, IEC 61010-2-032, IEC 61326 Power source R03 (1.5V) × 2* Continuous measuring time:DCV: approx. 150hours, ACA: approx. 25hours(Auto power save: approx. 15 minutes) Dimensions 128 (L) × 92 (W) × 27 (D) mm Weight 220g approx. (including batteries) Included Accessories R03 (1.5V) × 2, Instruction manual Optional Accessories 9107 (Carrying case [Soft]) Accessories/Optional Accessories /Related ProductsMODEL 9107[...]



KEWMATE 2000 - Digital Multimeter with AC/DC Clamp Sensor

Mon, 03 Oct 2016 07:24:00 +0000

Jual Digital Multimeter Kyoritsu KEWMATE 2000

• Capable of measuring AC and DC currents up to 60A with OPEN CLAMP SENSOR.
• 3400 counts with bargraph display.
• Pocket size and heavy duty design.

(image)
• Capable of measuring AC and DC currents up to 60A with OPEN CLAMP SENSOR.
• 3400 counts with bargraph display.
• Pocket size and heavy duty design.
How to put test lead in.
(image)
DC V 340mV/3.4/34/340/600V (Input Impedance: 10MΩ)
±1.5%rdg±4dgt
AC V 3.4/34/340/600V (Input Impedance: 10MΩ)
±1.5%rdg±5dgt [50 - 400Hz]
DC A 60A ±2%rdg±5dgt
AC A 60A ±2%rdg±5dgt (50/60Hz)
Ω 340Ω/3.4/34/340kΩ/3.4/34MΩ
±1%rdg±3dgt (0 - 340kΩ)
±5%rdg±5dgt (3.4MΩ)
±15%rdg±5dgt (34MΩ)
Continuity buzzer Buzzer sounds below 30±10Ω
(Continuity buzzer works on 340Ω range only)
Frequency (AC A) 3.4/10kHz ±0.1%rdg±1dgt
(AC V) 3.4/34/300kHz ±0.1%rdg±1dgt
(Input sensitivity Current: more than 15A, Voltage: more than 30V)
Conductor size Ø6mm max.
Applicable standards IEC 61010-1 CAT III 300V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326-1
Power source R03 (DC 1.5V) × 2
* Continuous measuring time: approx. 45 hours
(Auto power save: approx. 10 minutes)
Dimensions 128(L) × 87(W) × 24(D)mm
Weight 210g approx.
Included Accessories R03 (DC 1.5V) × 2, Instruction Manual
Optional Accessories 9107 (Carrying case [Soft])



Kyoritsu Indonesia - Multimeters

Sat, 04 Apr 2015 20:16:00 +0000

 Kyoritsu Indonesia - Jual Kyoritsu dengan harga Murah


Kyoritsu Indonesia ,Digital Multimeter with AC/DC Clamp Sensor ,Analogue Multimeters ,Digital Multimeters ,KEW2012R ,KEW2000 ,KEW2001 ,KEW1051/1052 ,KEW1061/1061 ,KEW1012 ,KEW1011 ,KEW1030 ,KEW1018/1018H ,1009 ,#Kyoritsu





Kyoritsu Indonesia Product - Jual Kyoritsu dengan harga murah

Sat, 04 Apr 2015 20:11:00 +0000

Kyoritsu Indonesia - Jual Kyoritsu Harga Murah


PT. Best Instrument Indonesia has a pool of experienced sales staff that can quickly troubleshoot problems, formulate cost effective solution which customers can be assured of the very best in today's stringent demands imposed by the end users.






Kyoritsu Indonesia - Jual Kyoritsu Harga Murah

Sat, 04 Apr 2015 20:08:00 +0000

Kyoritsu Indonesia - Jual Kyoritsu Harga Murah


PT. Best Instrument Indonesia are agent of ED, Delorenzo, Tektronix, Keithley, Kyoritsu, Tecnotest, Respirex, Electrosoft. We are always moving ahead to look for new product lines to compliment its existing range to meet market demands and to venture further into other market sectors in Asiapacific region.






About us

Tue, 11 Jun 2013 04:34:00 +0000

We are specialist supplier of Test Instrumentation and Industrial Control Components and an experienced provider of Application Solutions. Our products are sourced from some of the World's leading manufacturers, whose brands are well known and respected in the industry.We are sell Anritsu, ED, Delorenzo, Tektronix, Keithley, Kyoritsu, Tecnotest, Respirex, Electrosoft. We are always moving ahead to look for new product lines to compliment its existing range to meet market demands and to venture further into other market sectors in Asiapacific region.We have a pool of experienced sales staff that can quickly troubleshoot problems, formulate cost effective solution which customers can be assured of the very best in today's stringent demands imposed by the end users.[...]



Agilent Indonesia - InfiniiVision 4000 X-Series DSO and MSO Oscilloscopes

Wed, 15 May 2013 09:44:00 +0000

InfiniiVision 4000 X-Series DSO and MSO Oscilloscopes 

 

The oscilloscope experience redefined
Experience the speed:
  • Industry’s fastest 1,000,000 waveforms/sec update rate
  • MegaZoom IV uncompromised smart memory technology
  • Standard segmented memory
Experience the usability:
  • Industry-exclusive capacitive touch screen technology and interface designed for touch
  • Industry’s largest 12.1-inch display
  • Innovative InfiniiScan Zone touch triggering
Experience the integration:
  • Get 5 instruments in 1: oscilloscope, logic analyzer (MSO), serial protocol analyzer (including USB), dual-channel WaveGen, and 3-digit voltmeter
  • Full upgradability, including bandwidth



Agilent Indonesia - InfiniiVision 3000 X-Series DSO and MSO Oscilloscopes

Wed, 15 May 2013 09:42:00 +0000

InfiniiVision 3000 X-Series DSO and MSO Oscilloscopes 

 

Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
  • 100 MHz to 1 GHz
  • DSO or MSO (16 digital channels)
  • 1,000,000 waveforms/sec update rate
  • 2 Mpts memory standard (4 Mpts optional)
  • Built-in 20 MHz function/arbitrary waveform generator (optional)
  • Integrated digital voltmeter (optional)
  • Standard 3-year warranty, like all Agilent instruments



Agilent Indonesia - InfiniiVision 2000 X-Series Oscilloscope

Wed, 15 May 2013 09:39:00 +0000

InfiniiVision 2000 X-Series Oscilloscope

 

Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
  • 70 MHz to 200 MHz
  • DSO or MSO (8 digital channels)
  • Standard 5 year factory warranty
  • Up to 1 Mpts memory
  • Built-in 20 MHz function generator (optional)
  • Integrated 3-digit voltmeter (optional)
  • Serial triggering and analysis for CAN, LIN, I²C, SPI and RS232/422/485/UART (optional)